欧美中文亚洲V在线,春药刺激国产老富婆露脸,欧洲肉欲k8播放毛片,亚洲欧美日韩综合一区在线观看

Skip to main content

Ultra Inert (UI) Columns have consistent inertness performance from column to column.

Ultra Inert (UI) GC Columns push industry standards for consistent column inertness in a variety of stationary phase polarities. Gas Chromatography (GC) column inertness is critical, as columns contribute toward the largest surface area within an inert flow path. As samples become increasingly active and more complex, you cannot afford interferences introduced by the analytical flow path, such as GC columns, liners, septa. A non-inert GC column can cause both peak tailing and signal loss, and can also take or hide components in your sample, so you would never know what was missing. Repeating or verifying suspect analyses wastes resources, hinders productivity, and is more expensive. To achieve the lower detection limits demanded by tough regulatory demands and quantify active analytes with confidence, an Ultra Inert GC Column is required.

The new J&W 5Q columns combine industry-leading Ultra Inert performance with Ultra Low-Bleed technology, delivering the new standard for GC/MS column performance and productivity.

Didn’t find the GC column you need? A custom GC column can be built to order

Ultra Inert (UI) GC Columns

所有類別

精選工具

GC Column Selector Tool

Tools to help navigate to the best GC column choice for your application.

GC Calculators and Method Translation Software

Calculators and software for optimizing current gas chromatography (GC) methods or starting a new GC method.

GC Productivity Tools

Download method translation software plus calculators for vapor volume, pressure flow, solvent vent, and CFT.

精選客戶評(píng)價(jià)

Phillip Lynch

Lead Chemist, US Cannalytics

The new 5Q columns were essentially a plug and play update to our aging HP 5MS UI columns. We have noticed a decrease in the amount of noise/bleed from the columns themselves during the high ramp temperature regions of our analytical pesticide method. This has allowed us to add additional analytes to our method for orthogonal analysis between LC and GC techniques and therefore increasing our confidence during reporting. The attached chromatogram shows chlordanes at 0.5 ppb in-vial on a cannabis concentrate-type matrix. We are very satisfied with the column's performance in regard to retention time shifting, overall bleed reduction, and reproducibility.

查看更多

Dr. Frank David

Principal Scientist, RIC Group

The broad portfolio of Agilent columns that are available is really a key aspect in developing methods. What is also very important is that we have a broad range of lengths, internal diameters and film thicknesses.

查看更多

Dawei Zhang

Technical Director, SEP

Agilent GC columns are very durable and have good reproducibility, effectively ensuring the analysis and processing of everyday samples.

查看更多

Dr. Dan Villalanti

President and Founder, Triton Analytics

We have also been a long time user of the J&W Columns and we exclusively use those for high temp simulated distillation using the steel columns. Because of the nature of our work, we take the columns routinely every 50 minutes to about

查看更多
返回頁首
精選視頻
返回頁首
精選新聞

Agilent Launches New J&W Ultra Inert Columns with Ultra Low-Bleed Technology

The new J&W 5Q columns combine Agilent's industry-leading Ultra Inert performance with Ultra Low-Bleed technology, delivering the new standard for MS column performance and productivity. 5Q columns provide exceptional peak symmetry and minimal column bleed enabling high sensitivity, mass spectral integrity, and accurate quantitation for the most challenging, trace-level analytes. 5Q columns are also designed to optimize sample throughput with fast conditioning and outstanding durability even at high operating temperatures.

0 選擇的 COUNT_HERE 產(chǎn)品.

全部清除